简介:
?
BHQ-2 amine is a dark quencher that can beconjugated to target substrates or biomolecules containing a carboxylatemoiety. The BHQ-2 amine is for solution phase conjugations only. We do notrecommend using this product for labeling of peptides and proteins
外观:黑紫色粉末
Absorption Maximum (Lambda Max): 579nm
Storage Conditions: +2 to +8 °C
核磁图谱:
?
?
?
TCL点板纯度测试:
其他介绍:
Two commonly used quenchers, TAMRA? and DABYCL, limit the ultimatesensitivity and flexibility of qPCR. TAMRA is not a dark quencher and thereforecontributes to an overall increase in background because of its own nativefluorescence. DABCYL, though a dark quencher, has an inadequate absorptionfootprint that overlaps very poorly with reporter dyes emitting above 480 nm (Figure1).
Figure 1. Absorption spectra of DABCYL-T9with the emission spectra of the commonly-used reporters 6-FAM?, TET?, andJOE?. DABCYL was normalized at the poly-T absorbance (260 nm). RFU = relativefluorescence unit.
Though DABYCL works well in Molecular Beacons (structured probes withpaired reporter and quencher that utilize static quenching), its absorptionmaximum of 474 nm places it below the maxima of the reporters shown in?Figure1, therefore it is a poor choice forDual-Labeled Probes (linear probes with separated reporter and quencher thatutilize FRET quenching).
Black Hole Quencher 1 (BHQ?-1) (with an absorption maximum of534 nm) is absorbed at higher wavelengths than DABCYL and is directlysuperimposable with the emission maxima of FAM, TET and JOE. This provides asignificant increase in both static and FRET quenching efficiencies, whichmakes it an excellent quencher for Molecular Beacons and Dual-Labeled Probes.As shown in?Figure 2, BHQ-1, BHQ-2, and BHQ-3 cover thespectrum from 480 nm into the near IR making it possible to utilize reportersthat emit anywhere in this range.
Figure 2. Absorption spectra of the threeBHQ variants (conjugated to T-9 and normalized to the poly-T absorbance of 260nm) with the emission maxima of the commonly-used reporters 6-FAM, TET, HEX?,Cyanine 3, TAMRA, ROX?, LC Red 640, and Cyanine 5.
In addition to better spectral overlap, BHQ probes have much highersignal-to-noise ratios when compared to the corresponding DABCYL or TAMRAprobes (Figure 3).
?
Figure 3. Signal-to-noise (S:N) ratios werecalculated by dividing the fluorescence signal of a 25mer in the presence of afive-fold excess of an exact complementary target sequence by the fluorescenceintensity of the probe alone.
Finally, as shown in?Figure 4,the BHQ variants readily permit single-tube multiplexing due to the increasedvariety of reporters that can be effectively quenched with little or nocross-talk. This simplifies the design, implementation, and interpretation ofmultiplexed assays.
Figure 4. The unique characteristics of theBHQ variants permit flexibility in the choice of spectrally well-resolvedreporters, which enable single-tube multiplexing with little or no cross-talk.
In summary, Black Hole Quencher:
1.??????has no native fluorescence(emits heat instead of light), resulting in lower background fluorescence
2.??????has increasedsignal-to-noise ratio, providing higher sensitivity
3.??????enables a wider choice ofreporters for multiplexing
参数信息 |
外观状态: |
固体或粉末 |
质量指标: |
95%+ |
溶解条件: |
有机溶剂/水 |
CAS号: |
N/A |
分子量: |
N/A |
储存条件: |
-20℃避光保存 |
储存时间: |
1年 |
运输条件: |
室温2周 |
生产厂家: |
苏州北科纳米科技有限公司 |
留言咨询
|
|
生物纳米材料前沿 |
|
纳米医学Frontier |
|
温馨提示:苏州北科纳米供应产品仅用于科研,不能用于人体,不同批次产品规格性能有差异。网站部分文献案例图片源自互联网,图片仅供参考,请以实物为主,如有侵权请联系我们立即删除。
提示说明:纳米材料工艺和制备可能会有改变 所有纳米材料均支持按需定制 下单前联系客服确认产品详细信息。 |